Actuator size |
Effective Diaphragm
Area cm²
|
Air Supply
Kpa G
|
Spring range
Kpa G
|
Output thrust
N
|
220 | 188.8 | 400 | 120~300 | 2177 |
270 | 314.3 | 400 | 120~300 | 3648 |
350 | 555.8 | 400 | 120~280 | 6472 |
450 | 956.8 | 400 | 120~280 | 11180 |
550 | 1548.8 | 400 | 120~280 | 18028 |
650 | 2236.3 | 300 | 80~200 | 16475 |
650 | 2236.3 | 400 | 120~280 | 26050 |
Actuator Size
Stroke(mm)
20
25
30
40
50
60
70
80
90
100
110
220
0.7
270
1.31
1.46
1.6
350
2.25
2.52
2.78
3.3
450S
4.18
4.64
5.09
6
450L
7.28
8.18
9.09
10
10.91
550S
8.1
9.6
11.6
13
14.5
550L
16
17.4
19.1
21
650S
22.75
24.83
26.92
29
650L
32.67
34.75
36.83
38.92
41
Part
1
2
3
4
5
6
7
Content
Series
Size
Stroke
Drive Rod Position
Air Supply/Spring Range
Manual
Override
Ambient Temperature
Code
HPD
220
12
O(Air to Close. FO)
3(300/80-200KpaG)
N-None
1-standard(-10~70℃)
270
16
C(Air to Open. FC)
4(400/120-300KpaG)
M-Side handle
manual.
3-High temp.(0~100℃)
350
20
S(Special)
5(400/120-280KpaG)
S-Special
5-Low temp.(-40~40℃)
450
25
550
……
650
110
Example:HPD-550*110-O3M1
Company name
Whatsapp number
*Phone No.
*Share your ideas
[email protected]
+86-15810403962
+86-15810403962
+86-15810403962
+86-(0)10-63260308